35179| Код | 35179 |
|---|---|
| Мярка | бр. |
Аналогов двуканален осцилоскоп.
| Technical Data | CQ5660 | |||
| CRT | ||||
| Type | 6" rectangle, internalgraticule, 0%, 10%, 90% and 100% marks | |||
| Display area | 8 x 10DIV (DIV=10mm) | |||
| Accelerating voltage | 12kV | |||
| Intensity and focusing | Continuously adjustable at front panel | |||
| Trace rotation | Adjusted at the front panel | |||
| VERTICAL SYSTEM | ||||
| Sensitivity and accuracy | 1mV / DIV~5V / DIV ±3% 12 calibration steps in 1-2-5 sequence | |||
| Trimming ratio | ≥2.5:1 | |||
| Width of band (-3dB) | DC(AC 10Hz) ~60MHz | |||
| Rise Time | ≤5.83ns | |||
| 400V (DC + ACpeak) | ||||
| AC, DC, GND | ||||
| Input Impedance | 1MΩ±3% 25pF±5pF | |||
| Vertical Mode | CH1, CH2, DUAL (CHOP, ALT) ADD, CH2 inverse | |||
| HORIZONTAL SYSTEM | ||||
| Sweep time | 0.1us~0.1s / DIV | |||
| ±3%, ±5% at x10MAG (20nS~50nS/DIV uncalibrated) | ||||
| Trimming ratio | ≥2.5:1 | |||
| Sweep magnificaton | x10MAG | |||
| Max sweep time | 10nS/DIV | |||
| TRIGGER SYSTEM | ||||
| Trigger Modes | AUTO,NORM,TV-V,TV-H | |||
| Trigger Source | ALT, CH1, CH2, EXT, LINE | |||
| Trigger Polarity | "+" or "-" | |||
| Trigger sensitivity | 1 | 20Hz~2MHz | 2MHz~20MHz | 20MHz~60MHz |
| CH1 , CH2 | 0.5DIV | 1.5DIV | 2DIV | |
| ALT | 2DIV | 3DIV | 3DIV | |
| EXT | 0.2DIV | 0.8DIV | 0.8DIV | |
| TV sync pulse >1DIV or 1V (EXT) | ||||
| External trigger input | Input impedance: 1MΩ±3% 25pF±5pF | |||
| Max. input voltage: 300V (DC+ACpeak) at 1KHz | ||||
| FREQUENCY COUNTER | ||||
| Display | 6 digits LED | |||
| Accuracy | 1Hz(0~1MHz),10Hz (1MHz~10MHz),100Hz (10MHz~60MHz) | |||
| Sensitivity | Same as trigger system | |||
| X-Y OPERATION | ||||
| Sensitivity and accuracy | 5mV~5V/DIV, ±5% 10 calibration steps 1-2-5 sequence | |||
| Width of band (-3dB) | DC (AC 10Hz) ~500kHz | |||
| Phase difference | ≤3°or less from DC to 50kHz | |||
| Axis Z | ||||
| Sensitivity | 5Vp-p | |||
| Polarity | Negative going input increase intensity | |||
| Input impedance | 47KΩ | |||
| Usable frequency range | DC~2MHz | |||
| Max. input voltage | 30V (DC+AC peak) at 1kHz | |||
| CALIBRATION | Voltage: 2Vp-p±2%, Frequency: 1KHz±2%, Square wave | |||
| POWER SOURCE | 110~127 VAC±10%, 220~240VAC±10%, 50Hz±2Hz / 60Hz±2Hz | |||
| ACCESSORIES | Instruction manual x 1, Power cable x 1 ,Fuse x 1, Probe x 2 | |||
| DIMENSIONS & WEIGHT | 316mm x 132mm x 410mm Approx 7.8kg | |||
Описание
Аналогов двуканален осцилоскоп. Technical Data CQ5660 CRT Type 6" rectangle, internalgraticule, 0%, 10%, 90% and 100% marks Display area 8 x 10DIV (DIV=10mm) Accelerating voltage 12kV Intensity and focusing Continuously adjustable at front panel Trace rotation Adjusted at the front panel VERTICAL SYSTEM Sensitivity and accuracy 1mV / DIV~5V / DIV ±3% 12 calibration steps in 1-2-5 sequence Trimming ratio ≥2.5:1 Width of band (-3dB) DC(AC 10Hz) ~60MHz Rise Time ≤5.83ns 400V (DC + ACpeak) AC, DC, GND Input Impedance 1MΩ±3% 25pF±5pF Vertical Mode CH1, CH2, DUAL (CHOP, ALT) ADD, CH2 inverse HORIZONTAL SYSTEM Sweep time 0.1us~0.1s / DIV ±3%, ±5% at x10MAG (20nS~50nS/DIV uncalibrated) Trimming ratio ≥2.5:1 Sweep magnificaton x10MAG Max sweep time 10nS/DIV TRIGGER SYSTEM Trigger Modes AUTO,NORM,TV-V,TV-H Trigger Source ALT, CH1, CH2, EXT, LINE Trigger Polarity "+" or "-" Trigger sensitivity 1 20Hz~2MHz 2MHz~20MHz 20MHz~60MHz CH1 , CH2 0.5DIV 1.5DIV 2DIV ALT 2DIV 3DIV 3DIV EXT 0.2DIV 0.8DIV 0.8DIV TV sync pulse >1DIV or 1V (EXT) External trigger input Input impedance: 1MΩ±3% 25pF±5pF Max. input voltage: 300V (DC+ACpeak) at 1KHz FREQUENCY COUNTER Display 6 digits LED Accuracy 1Hz(0~1MHz),10Hz (1MHz~10MHz),100Hz (10MHz~60MHz) Sensitivity Same as trigger system X-Y OPERATION Sensitivity and accuracy 5mV~5V/DIV, ±5% 10 calibration steps 1-2-5 sequence Width of band (-3dB) DC (AC 10Hz) ~500kHz Phase difference ≤3°or less from DC to 50kHz Axis Z Sensitivity 5Vp-p Polarity Negative going input increase intensity Input impedance 47KΩ Usable frequency range DC~2MHz Max. input voltage 30V (DC+AC peak) at 1kHz CALIBRATION Voltage: 2Vp-p±2%, Frequency: 1KHz±2%, Square wave POWER SOURCE 110~127 VAC±10%, 220~240VAC±10%, 50Hz±2Hz / 60Hz±2Hz ACCESSORIES Instruction manual x 1, Power cable x 1 ,Fuse x 1, Probe x 2 DIMENSIONS & WEIGHT 316mm x 132mm x 410mm Approx 7.8kg