Документи и подобни
Технически характеристики
38579| Код | 38579 |
|---|
Цифров двуканален осцилоскоп с цветен дисплей и памет.
| Technical Data | DQ3062 | |
| BANDWIDTH | 60MHz | |
| REAL TIME SAMPLE RATE | 250MS/s | |
| DISPLAY | 3.8 inch color display with TFT panel(320x240 pixels) | |
| ACQUISITION MODE | Normal, Peak detect, Averaging | |
| INPUT | ||
| Input coupling | DC, AC | |
| Input impedance | 1M±2% in parallel with 20pF±3pF | |
| Probe attenuation factors | 1x, 10x, 100x, 1000x | |
| Max. input voltage | 400V(PK-PK) CATII | |
| HORIZONTAL SYSTEM | ||
| Saming range | 10S/s~250MS/s | |
| Recoord length | Max. 6K points | |
| Time base range | 5ns/div~50s/div(step as 1~2.5~5) | |
| Time base accuracy 100ppm | 400V (DC + ACp-p) | |
| VERTICAL SYSTEM | ||
| Resolution | 8 bits | |
| Sensitivity | 5mV/div~5V/div (input to BNC) | |
| Position range | ±2V (5mV~200mV) | |
| Single bandwidth | Full bandwidth | |
| LF Respong(AC, -3dB) | ≥5Hz( to BNC) | |
| Rising time(typical on BNC) | ≤17.5 ns | |
| DC gain accuracy | ±5% | |
| TRIGGER | ||
| Trigger Modes | AUTO, NORM, Single, Edge, Video | |
| Trigger sensitivity | DC coupling: CH1 and CH2: 1div(DC~25M) AC coupling: CH1 and CH2: 1div(50Hz~full bandwidth) |
|
| Trigger level range | ±6 divisions from center screen | |
| Trigger level accuracy | ±0.3 divisions | |
| Trigger sensitivity(Video) | 2 div(PK-PK) | |
| Line/field frequency(Video) | Support NTSC, PAL and SECAM | |
| MEASUREMENT SYSTEM | ||
| Cursors measurement | ΔV, ΔT | |
| Automatic measurement | PK-PK, Averaging, RMS, Frequency, Circle | |
| Waveform math | +, -, x, ÷ | |
| Waveform storage | 4 waveforms, 4 settings | |
| Lissajou's figure | Available | |
| PROBE | ||
| Bandwidth | DC~full bandwidth(10x) | |
| Attenuation rate | 10:1 (10x) | |
| Compensate range | 10pf~35pf | |
| Input impedance | 1M±2% | |
| Input capacitance | 14.5pf~17.5pf | |
| Input voltage | 300V DC | |
| ADPATER | ||
| Output current | 8.5V DC 1500mA | |
| LI-ION BATTERY POWER SUPPLY | 7.4V, 3500mA | |
| DIGITAL MULTIMETER CHARACTERISTS | ||
| Input impdeance | 10M | |
| Voltage | VDC: 400mV, 4V, 400V:±(1%+1 digit) Max. input: DC 400V VAC: 4V, 40V, 400V: ±(1%+3 digits) Fuequency: 40Hz~400Hz Max.input: AC 400V(virtual value) |
|
| Current | 20A:±(3%+3 digits) 20A:±(5%+3 digits) |
|
| Impedance | 400:±(1%+3 digits) 4K, 40K, 400K, 4M:±(1%+1 digit) 40M:±(1.5%+3 digits) |
|
| Capacitance | 51.2nF~100uF:±(3%+3 digits) | |
| Diode | 0V~1.5V | |
| On/off measurement | <50(±30) beeping | |
| ACCESSORIES | Two probes, two multimeter leads, current measurement extend module, probe adjust pen, small capacitance mesurement module, USB cable(RS232 optional), adapter | |
Описание
Цифров двуканален осцилоскоп с цветен дисплей и памет. Technical Data DQ3062 BANDWIDTH 60MHz REAL TIME SAMPLE RATE 250MS/s DISPLAY 3.8 inch color display with TFT panel(320x240 pixels) ACQUISITION MODE Normal, Peak detect, Averaging INPUT Input coupling DC, AC Input impedance 1M±2% in parallel with 20pF±3pF Probe attenuation factors 1x, 10x, 100x, 1000x Max. input voltage 400V(PK-PK) CATII HORIZONTAL SYSTEM Saming range 10S/s~250MS/s Recoord length Max. 6K points Time base range 5ns/div~50s/div(step as 1~2.5~5) Time base accuracy 100ppm 400V (DC + ACp-p) VERTICAL SYSTEM Resolution 8 bits Sensitivity 5mV/div~5V/div (input to BNC) Position range ±2V (5mV~200mV) Single bandwidth Full bandwidth LF Respong(AC, -3dB) ≥5Hz( to BNC) Rising time(typical on BNC) ≤17.5 ns DC gain accuracy ±5% TRIGGER Trigger Modes AUTO, NORM, Single, Edge, Video Trigger sensitivity DC coupling: CH1 and CH2: 1div(DC~25M) AC coupling: CH1 and CH2: 1div(50Hz~full bandwidth) Trigger level range ±6 divisions from center screen Trigger level accuracy ±0.3 divisions Trigger sensitivity(Video) 2 div(PK-PK) Line/field frequency(Video) Support NTSC, PAL and SECAM MEASUREMENT SYSTEM Cursors measurement ΔV, ΔT Automatic measurement PK-PK, Averaging, RMS, Frequency, Circle Waveform math +, -, x, ÷ Waveform storage 4 waveforms, 4 settings Lissajou's figure Available PROBE Bandwidth DC~full bandwidth(10x) Attenuation rate 10:1 (10x) Compensate range 10pf~35pf Input impedance 1M±2% Input capacitance 14.5pf~17.5pf Input voltage 300V DC ADPATER Output current 8.5V DC 1500mA LI-ION BATTERY POWER SUPPLY 7.4V, 3500mA DIGITAL MULTIMETER CHARACTERISTS Input impdeance 10M Voltage VDC: 400mV, 4V, 400V:±(1%+1 digit) Max. input: DC 400V VAC: 4V, 40V, 400V: ±(1%+3 digits) Fuequency: 40Hz~400Hz Max.input: AC 400V(virtual value) Current 20A:±(3%+3 digits) 20A:±(5%+3 digits) Impedance 400:±(1%+3 digits) 4K, 40K, 400K, 4M:±(1%+1 digit) 40M:±(1.5%+3 digits) Capacitance 51.2nF~100uF:±(3%+3 digits) Diode 0V~1.5V On/off measurement <50(±30) beeping ACCESSORIES Two probes, two multimeter leads, current measurement extend module, probe adjust pen, small capacitance mesurement module, USB cable(RS232 optional), adapter
Наличност в магазини
Склад 0 бр. · магазини 0 бр.
Отзиви и въпроси
Трябва да сте влезли в профила си за да коментирате!